Comparison Between Placenta Accreta Index and Tovbin Score as A Predictor of Placenta Accreta Spectrum Disorders (PASD)

Authors

  • Willy Angga Dinata Obstetric and gynecology Division, Medical Faculty of Diponegoro University/Central General Hospital of Kariadi Semarang, Indonesia, Indonesia
  • Alini Hafiz Obstetric and gynecology Division, Medical Faculty of Diponegoro University/Central General Hospital of Kariadi Semarang, Indonesia, Indonesia
  • Arufiadi Anityo Mochtar Obstetric and gynecology Division, Medical Faculty of Diponegoro University/Central General Hospital of Kariadi Semarang, Indonesia, Indonesia
  • Julian Dewantiningrum Obstetric and gynecology Division, Medical Faculty of Diponegoro University/Central General Hospital of Kariadi Semarang, Indonesia, Indonesia
  • Putri Sekar Wiyati Obstetric and gynecology Division, Medical Faculty of Diponegoro University/Central General Hospital of Kariadi Semarang, Indonesia, Indonesia
  • Ratnasari Dwi Cahyanti Obstetric and gynecology Division, Medical Faculty of Diponegoro University/Central General Hospital of Kariadi Semarang, Indonesia, Indonesia

DOI:

https://doi.org/10.36408/mhjcm.v11i1.980

Keywords:

PAI, PASD, Placenta Accreta, Tovbin Score

Abstract

Background : The incidence of  Placenta Accreta Spectrum Disorders (PASD) in developed countries has reportedly increased 10-fold in the last 50 years. The significant increase was followed by an increase in the number of caesarean section from 12.5% to 23.5% in the last 10 years. Maternal morbidity related to PASD events reaches 7% in intraoperative and postoperative actions, while the morbidity reaches 60%. In cases of late diagnosis, maternal mortality with placenta accreta reaches 30%. Efforts to prevent maternal morbidity and mortality can be carried out by early detection at antenatal care visits. The Placenta Accreta Index (PAI) and Tovbin scoring systems based on the results of ultrasound examination can be used to screening for placenta accreta.

Objective: To analyze the comparison of the accuracy of the PAI and Tovbin scoring systems in predicting the incidence of Placenta Accreta Spectrum Disorder (PASD).

Method: The study used an analytic observational with a cross sectional design. Sampling was done by consecutive sampling method. There were 35 subjects who met the inclusion and exclusion criteria. PAI and Tovbin scoring were performed on each selected subject. The accuracy of the PAI and Tovbin scoring systems was confirmed by establishing a diagnosis based on PASD histopathology.

Results: The PAI scoring system in predicting PASD has a sensitivity value of 79.31%, a specificity of 83.33%, a positive predictive value (NDP) of 95.83%, a negative predictive value (NDN) of 45.45%, an accuracy of 80.00%. While the Tovbin scoring system obtained a sensitivity value of 86.21%, specificity of 83.33%, NDP of 96.15%, NDN of 55.56%, accuracy of 85.71 %.

Conclusion: In the comparison of scoring systems, it was found that the Tovbin scoring system has almost the same sensitivity and accuracy and the same specificity in predicting Placenta Accreta Spectrum Disorder (PASD).

Downloads

Download data is not yet available.

References

 1. Jauniaux E, Chantraine F, Silver RM, Langhoff‐Roos J. <scp>FIGO</scp> consensus guidelines on placenta accreta spectrum disorders: Epidemiology,. International Journal of Gynecology & Obstetrics. 2018 Mar 6;140(3):265–73. doi:10.1002/ijgo.12407

2. Goh WA, Zalud I. Placenta accreta: diagnosis, management and the molecular biology of the morbidly adherent placenta. The Journal of Maternal-Fetal & Neonatal Medicine. 2015 Jul 2;1–6. doi:10.3109/14767058.2015.1064103

3. Gielchinsky Y, Rojansky N, Fasouliotis SJ, Ezra Y. Placenta Accreta—Summary of 10 Years: A Survey of 310 Cases. Placenta. 2002 Feb;23(2–3):210–4. doi:10.1053/plac.2001.0764

4. Jain C. ACOG Committee Opinion No. 723: Guidelines for Diagnostic Imaging During Pregnancy and Lactation. Obstetrics & Gynecology. 2019 Jan;133(1):186–186. doi:10.1097/AOG.0000000000003049

5. Farquhar CM, Li Z, Lensen S, McLintock C, Pollock W, Peek MJ, et al. Incidence, risk factors and perinatal outcomes for placenta accreta in Australia and New Zealand: a case–control study. BMJ Open. 2017 Oct 5;7(10):e017713. doi:10.1136/bmjopen-2017-017713

6. Rac MWF, Dashe JS, Wells CE, Moschos E, McIntire DD, Twickler DM. Ultrasound predictors of placental invasion: the Placenta Accreta Index. Am J Obstet Gynecol. 2015 Mar;212(3):343.e1-343.e7. doi:10.1016/j.ajog.2014.10.022

7. Tovbin J, Melcer Y, Shor S, Pekar‐Zlotin M, Mendlovic S, Svirsky R, et al. Prediction of morbidly adherent placenta using a scoring system. Ultrasound in Obstetrics & Gynecology. 2016 Oct 5;48(4):504–10. doi:10.1002/uog.15813

8. Bhide A, Sebire N, Abuhamad A, Acharya G, Silver R. Morbidly adherent placenta: the need for standardization. Ultrasound in Obstetrics & Gynecology. 2017 May 4;49(5):559–63. doi:10.1002/uog.17417

9. Stănculescu RV, Brătilă E, Socolov DG, Russu MC, Bauşic V, Chirculescu R, et al. Update on placenta accreta spectrum disorders by considering epidemiological factors, ultrasound diagnosis and pathological exam – literature review and authors’ experience. Romanian Journal of Morphology and Embryology. 2022 Nov 15;63(2):293–305. doi:10.47162/RJME.63.2.02

10. Cali G, Forlani F, Lees C, Timor‐Tritsch I, Palacios‐Jaraquemada J, Dall’Asta A, et al. Prenatal ultrasound staging system for placenta accreta spectrum disorders. Ultrasound in Obstetrics & Gynecology. 2019 Jun 6;53(6):752–60. doi:10.1002/uog.20246

11. Del Negro V, Aleksa N, Galli C, Ciminello E, Derme M, Vena F, et al. Ultrasonographic Diagnosis of Placenta Accreta Spectrum (PAS) Disorder: Ideation of an Ultrasonographic Score and Correlation with Surgical and Neonatal Outcomes. Diagnostics. 2020 Dec 25;11(1):23. doi:10.3390/diagnostics11010023

12. Cali G, Forlani F, Timor‐Trisch I, Palacios‐Jaraquemada J, Foti F, Minneci G, et al. Diagnostic accuracy of ultrasound in detecting the depth of invasion in women at risk of abnormally invasive placenta: A prospective longitudinal study. Acta Obstet Gynecol Scand. 2018 Oct 30;97(10):1219–27. doi:10.1111/aogs.13389

13. Chen L, Shi HF, Jiang H, Shi XM, Wang YY, Zhang AQ, et al. Correlation of An Ultrasonic Scoring System and Intraoperative Blood Loss in Placenta Accreta Spectrum Disorders: A Retrospective Cohort Study. Biomed Environ Sci. 2021 Feb 20;34(2):163–9. doi:10.3967/bes2021.022

14. Chong Y, Zhang A, Wang Y, Chen Y, Zhao Y. An ultrasonic scoring system to predict the prognosis of placenta accreta: a prospective cohort study. Medicine. 2018;97(35).

15. Agarwal S, Agarwal A, Chandak S. Role of placenta accreta index in prediction of morbidly adherent placenta: A reliability study. Ultrasound. 2021 May 22;29(2):92–9. doi:10.1177/1742271X20959742

16. Feharsal Y, Lisnawati Y, Pudyastuti S, Khonsa O, Apriliawan T, Nurfauziah N, et al. Clinical Characteristics and Risk Factors Analysis for Severity of Morbidly Adherent Placenta at Persahabatan General Hospital in 2015-2018. 2015.

17. CARUSI DA. The Placenta Accreta Spectrum: Epidemiology and Risk Factors. Clin Obstet Gynecol. 2018 Dec;61(4):733–42. doi:10.1097/GRF.0000000000000391

18. Yeni CM, Andayani H, Indirayani I, Razali R. The Association betweeen Cesarean Section and Placenta Accreta Hubungan antara Seksio Sesarea dan Plasenta Akreta.

19. Higgins MF, Monteith C, Foley M, O’Herlihy C. Real increasing incidence of hysterectomy for placenta accreta following previous caesarean section. European Journal of Obstetrics & Gynecology and Reproductive Biology. 2013 Nov;171(1):54–6. doi:10.1016/j.ejogrb.2013.08.030

20. Shi XM, Wang Y, Zhang Y, Wei Y, Chen L, Zhao YY. Effect of Primary Elective Cesarean Delivery on Placenta Accreta. Chin Med J (Engl). 2018 Mar 20;131(6):672–6. doi:10.4103/0366-6999.226902

21. Morlando M, Collins S. <p>Placenta Accreta Spectrum Disorders: Challenges, Risks, and Management Strategies</p>. Int J Womens Health. 2020 Nov;Volume 12:1033–45. doi:10.2147/IJWH.S224191

22. Lubis MP, Yaznil MR, Barus MNG, Asroel EM, Faustine M. Maternal Outcomes of Hysterectomy and Conservative Surgery in Placenta Accreta. Curr Womens Health Rev. 2020 Jul 22;16(3):201–5. doi:10.2174/1573404816666200303123850

23. Agarwal S, Agarwal A, Chandak S. Role of placenta accreta index in prediction of morbidly adherent placenta: A reliability study. Ultrasound. 2021 May 22;29(2):92–9. doi:10.1177/1742271X20959742

24. Yang JI, Lim YK, Kim HS, Chang KH, Lee JP, Ryu HS. Sonographic findings of placental lacunae and the prediction of adherent placenta in women with placenta previa totalis and prior Cesarean section. Ultrasound in Obstetrics & Gynecology. 2006 Aug 21;28(2):178–82. doi:10.1002/uog.2797

25. Verma P, Singh K, Ghanghoriya V. To study analyze maternal serum alpha-fetoprotein as a biomarker of placental adherence in low lying placenta. Int J Reprod Contracept Obstet Gynecol. 2016;1959–63. doi:10.18203/2320-1770.ijrcog20161698

26. Hassan M, Mosbeh M, Mohammed M, Mohammed H, Abd El-Raheim A. Myometrial thickness as a Predictor of Placenta Accretain cases with Placenta Previa Centeralis. Minia Journal of Medical Research. 2020 Jan 1;31(1):275–81. doi:10.21608/mjmr.2022.221523

27. Adu‐Bredu TK, Rijken MJ, Nieto‐Calvache AJ, Stefanovic V, Aryananda RA, Fox KA, et al. A simple guide to ultrasound screening for placenta accreta spectrum for improving detection and optimizing management in resource limited settings. International Journal of Gynecology & Obstetrics. 2023 Mar 18;160(3):732–41. doi:10.1002/ijgo.14376

28. Tovbin J, Melcer Y, Shor S, Pekar‐Zlotin M, Mendlovic S, Svirsky R, et al. Prediction of morbidly adherent placenta using a scoring system. Ultrasound in Obstetrics & Gynecology. 2016 Oct 5;48(4):504–10. doi:10.1002/uog.15813

Additional Files

Published

2024-03-28

How to Cite

1.
Dinata WA, Hafiz A, Mochtar AA, Dewantiningrum J, Wiyati PS, Cahyanti RD. Comparison Between Placenta Accreta Index and Tovbin Score as A Predictor of Placenta Accreta Spectrum Disorders (PASD). Medica Hospitalia J. Clin. Med. [Internet]. 2024 Mar. 28 [cited 2024 Dec. 3];11(1):26-32. Available from: http://medicahospitalia.rskariadi.co.id/medicahospitalia/index.php/mh/article/view/980

Issue

Section

Original Article

Citation Check